Home Up Call me back Contents Contact Immunology / Infectious agents / Cellular Biology / Molecular biology / Instruments / Lentiviral Technology / RNAi Libreries / Stem Cell Research / MicroRNA / Proteomics / Chemicals / Campaign / Antibodies Myeloperoxidase Detection 

Google

       Pricelist 2010 

Home
Up

redcoon België GENTAUR BVBA

VAT BE0473327336

Av. de l Armee 68 B4

1040 Brussels BELGIUM

  Tel + 32 16 58 90 45 

Fax + 32 16 50 90 45

GENTAUR France SARL

SIRET 48423788800017

Rue Lagrange, 9

75005 Paris, France

 Tel 01 43 25 01 50

Fax 01 43 25 01 60 

GENTAUR Germany

52074 Aachen, Germany

 Tel 0241 40 08 90 86

Fax 0241 55 91 05 36

GENTAUR Pol Sp. Z.o.o. Ulica Ogarna 15/19B m2

80-826 GDANSK

Tel 00 48 51 760 77 08

Fax: 00 32 16 50 90 45

GENTAUR Italy

23015 Milano, Italy

 Tel 02 36 00 65 93

Fax 02 36 00 65 94

Česká republika Praha
+420246019719
 

Danmark

+4569918806 

Finland Helsset
+358942419041

Ελλάς Αθήνα
+302111768494
 

Ireland Dublin
+35316526556
 

Luxembourg
+35220880274
 

Magyarország Budapest
+3619980547
 

Nederland
+31208080893
 

Norge Oslo
+4721031366
 

Österreich
+43720880899
 

Sverige Stockholm
+46852503438
 

Schweiz Züri
+41435006251
 

 

Northern America 

Canada Montreal
+15149077481
 

US New York
+17185132983

 

Other Countries redcoon België
0032 (0)16 41 44 07

 

Cellufine Phenyl en Butyl
For purification of proteins and macromolecules.

Hydrophobic Interaction Chromatography (HIC) is a method which separates proteins on the basis of their differential interactions with a mildly hydrophobic surface.

HIC media are porous chromatography particles, manufactured from crosslinked cellulose to which either a butyl, phenyl or octyl functionality has been covalently bonded via a short spacer.

Factors which affect hydrophobic interactions include: salt concentrations, temperature, pH, surfactant and organic solvents. Usually the higher the ionic strength (salt concentration) the stronger the hydrophobic bond. Consequently the interaction is enhanced by conditions inverse to that of ion exchange chromatography. HIC is, therefore, an effective complementary tool for separating and purifying substances which are difficult or cannot be separated by ion exchange.

Partial Structure:

Butyl, Phenyl & Octyl


Features:

• Spherical particles exhibiting high mechanical strength
• Butyl, Phenyl, Octyl functionality
• Pre-swollen
• Virtually no shrinkage or swelling
• Stable in organic solvents and surfactants
• Stable coupling chemistry
• Resistant to 0.2 M NaOH
• Autoclavable (121 °C, 20 min)


Benefits:

• High flow rates allowing rapid chromatography and direct scale-up
• Enables optimum selectivity to be obtained
• Easy packing
• Easy large scale operation. No shrinkage at high salt concentrations
• Enables range of solvent systems to be utilized
• Resistant to cleaning and elution conditions
• Sterilizable
• Regulatory support

Hydrophobicity of Matrix:

The degree of hydrophobicity increases in the order of Butyl < Phenyl < Octyl. In general hydrophobic proteins will be more strongly adsorbed to Cellufine Octyl than Cellufine Butyl. However, if the protein is too strongly adsorbed, difficulty may be experienced in elution. The aromatic nature of the Cellufine Phenyl may, in certain cases, give improved selectivity compared to either the Butyl or Octyl matrices. Consequently it is difficult to generalize and each application needs to be evaluated separately to select the optimal media functionality.

 Figure1

Column : 8.2 x 150 mm
Column Vol. : 8 ml
Buffer : 2.0 – 0.0M
Ammonium Sulfate
in 0.01M phosphate, pH 7.0
Flow Rate : 1.32 ml/min
Sample : 5 mg/3 ml– 100 µl

 

 

 

 


Figure 1. The retention increases with an increase in the carbon chain and aromatic structure of the functional group as a result of stronger hydrophobic interaction.

Flow Properties:
The semi-rigid structure of Cellufine HIC, combined with the spherical bead shape, gives excellent flow rates with higher operating pressures. Flow rates in excess of 100 cm/hr are achieved at pressure drops of 1 bar, even in large diameter process columns.

Figure2

 

 Buffer : 0.01M Phosphate buffer (pH 7.0)
 Temperature : 23 °C
 Columns : (a) 22 x 300 mm
 (Vc = 0.11 liters)
 (b) 90 x 200 mm
 (Vc = 1.27 liters)
 (c) 250 x 250 mm
 (Vc = 12.26 liters)

 

 

 

 

Adsorption Capacity and Recovery Ratio: