Home Up Call me back Contents Contact Immunology / Infectious agents / Cellular Biology / Molecular biology / Instruments / Lentiviral Technology / RNAi Libreries / Stem Cell Research / MicroRNA / Proteomics / Chemicals / Campaign / Antibodies Myeloperoxidase Detection 

Google

       Pricelist 2010 

Home
Up

redcoon België GENTAUR BVBA

VAT BE0473327336

Av. de l Armee 68 B4

1040 Brussels BELGIUM

  Tel + 32 16 58 90 45 

Fax + 32 16 50 90 45

GENTAUR France SARL

SIRET 48423788800017

Rue Lagrange, 9

75005 Paris, France

 Tel 01 43 25 01 50

Fax 01 43 25 01 60 

GENTAUR Germany

52074 Aachen, Germany

 Tel 0241 40 08 90 86

Fax 0241 55 91 05 36

GENTAUR Pol Sp. Z.o.o. Ulica Ogarna 15/19B m2

80-826 GDANSK

Tel 00 48 51 760 77 08

Fax: 00 32 16 50 90 45

GENTAUR Italy

23015 Milano, Italy

 Tel 02 36 00 65 93

Fax 02 36 00 65 94

Česká republika Praha
+420246019719
 

Danmark

+4569918806 

Finland Helsset
+358942419041

Ελλάς Αθήνα
+302111768494
 

Ireland Dublin
+35316526556
 

Luxembourg
+35220880274
 

Magyarország Budapest
+3619980547
 

Nederland
+31208080893
 

Norge Oslo
+4721031366
 

Österreich
+43720880899
 

Sverige Stockholm
+46852503438
 

Schweiz Züri
+41435006251
 

 

Northern America 

Canada Montreal
+15149077481
 

US New York
+17185132983

 

Other Countries redcoon België
0032 (0)16 41 44 07

 

MagExtractor®-Plasmid-

This kit is for extraction of high purity plasmid DNA from bacteria such as E.coli. The recovered plasmid DNA can be used directly in enzymatic reactions including restriction endonuclease digestion and PCR sequencing and transformation. As this kit employs the principle that magnetic silica beads bind plasmid DNA present in a lysate solution, it is not necessary to perform deproteinization using harmful reagents such as phenol, or ethanol precipitation. Further, high-speed centrifugation is minimized, and if the MFX Series automatic nucleic acids extraction system is used it is not necessary at all. This kit is suitable for the MFX series automatic nucleic acids extraction system and can also be used as a manual kit for B/F (solid-liquid) separation using a magnetic beads separation stand.

Application:

Plasmid DNA Extraction from Bacteria such as E.coli
Recovered plasmid DNA can be used directly in various enzymatic reactions and transformations.

1. Restriction Endonuclease Processing of the Extracted Plasmid
Plasmid was extracted from 1.2 ml of the solution cultured overnight of JM109 transformant harboring pUC18, using this kit and another commercially available kit. There was hardly any contamination by proteins, genomic DNA or RNA, and the plasmid DNA yield using this kit was equal to or higher than that obtained with the other commercially available kit.
In addition, part of the obtained plasmid was digested with a restriction endonuclease, and the plasmid extracted with this kit as well as the other commercial available kit were confirmed to be completely digested.
The result shows the use of this kit allows extraction of high purity plasmid from bacteria such as E.coli.

2. Sequencing Analysis of the Extracted Plasmid
An ABI PRISM 310 Genetic Analyzer was used to perform sequencing using 0.5 µg of pUC18 extracted with this kit. The sequence primer used was M13 Primer P8 (Code No. PRM-005) and the sequence kit was dRhodamine Terminator Cycle Sequencing FS Ready Reaction Kit (PE Applied Biosystems).
The results show that plasmid extracted with this kit is of sufficient quality to be used in auto-sequencing.

Feature and Advantages:

  • Quick, Simple Extraction
    MagExtractor® -Plasmid- is based on the principle that magnetic silica beads bind
    plasmid DNA, providing simple extraction of plasmid DNA in a short time.
  • No Phenol or Chloroform Extraction
    This kit does not require the use of harmful phenol or chloroform so there is no
    hazardous waste problem.
  • Produces High Purity Plasmid DNA
    The plasmid DNA extracted with this kit contains hardly any impurities such as genomic DNA, RNA or proteins.

Procedure:

This kit, as a manual kit, extracts high purity plasmid DNA according to the following steps.

  1. Based on a similar principle to the alkali/SDS method, dissolve and neutralize the bacteria.
  2. Remove the supernatant dissolved in the plasmid DNA by centrifugal separation.
  3. Add Adsorption Solution containing chaotropic reagents and Magnetic Silica Beads and mix for the plasmid DNA in the sample to adhere to the silica's surface.
  4. Wash beads with Washing Solution and remove unwanted proteins, salts, etc.
  5. Elute and recover plasmid DNA from the beads with sterile water or low salt buffer, etc.

One-Point Advice:

  • B/F Separation
    Manual use of this kit is simplified with a magnetic beads separation stand.
    B/F separation may be performed using a compact desktop centrifuge instead of a magnetic beads separation stand.
  • Electrophoresis of Extracted Plasmid DNA
    Since the recovered plasmid DNA solution may contain some ethanol depending on the restriction endonuclease digestion grade method, it is possible that samples may not be immersed in the well with a standard loading dye. The use of the loading dye supplied in this kit is recommended.
  • Sample Amount for Extraction
    Excessive sample amounts may result in reduced plasmid DNA yields. We recommend a proper amount of sample be used 

__________________________________________________________________________________________________________________________